Report settings

Setup Item
Report notification
Report notification
Set the recipients that will receive report e-mails.
Scheduled settings
Setup Item
Scheduled notification
Attach instantaneous data
Interval (Recipient 1)
Ref. time hour (Recipient 1)
Ref. time minute (Recipient 1) 0 to 59
Interval (Recipient 2)
Ref. time hour (Recipient 2)
Ref. time minute (Recipient 2) 0 to 59
Scheduled notification
Set the recipients that will receive scheduled e-mail transmissions.
Attach instantaneous data
Set this to On to include instantaneous data. The data that is attached is the instantaneous
value at the scheduled times.
Interval (Recipient 1)
Set the interval for transmitting e-mails to recipient 1.
Ref. time hour, Ref. time minute (Recipient 1)
Set the time used as a reference for sending e-mails at specific intervals to Recipient 1.
Interval (Recipient 2)
Set the interval for transmitting e-mails to recipient 2.
Ref. time hour, Ref. time minute (Recipient 2)
Set the time used as a reference for sending e-mails at specific intervals to Recipient 2.

System settings

Setup Item
Selectable Range or Options
Memory full notification
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2
Power failure notification
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2
System error notification
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2
1
User lockout notification
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2
1 Appears for the advanced security function (/AS option).
Memory full notification
Sends a message when the free space on the external storage medium or internal memory
is low.
For details, see page 1-209 in section 1.23.6, "Setting the FAIL Relay and Instrument
Information Output (/FL option)"
Power failure notification
Set recipients if you want e-mails to be sent when the GX/GP is powered on or recovers
from a power failure.
System error notification
Set recipients if you want e-mails to be sent when system errors occur.
1.21 Configuring the Ethernet Communication Function
Selectable Range or Options
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2 Off
Selectable Range or Options
Off, Recipient 1, Recipient 2, Recipient 1 & Recipient 2 Off
Off, On
1h, 2h, 3h, 4h, 6h, 8h, 12h, 24h
0 to 23
1h, 2h, 3h, 4h, 6h, 8h, 12h, 24h
0 to 23
1
Default Value
2
3
Default Value
Off
24h
0
4
0
24 h
0
0
5
App
Index
Default Value
Off
Off
Off
Off
1-187