UM Group
DISA (1–64)
TAFAS (Pager)
ICD Group (1–64)
UM Channel (1–2)
FAX Channel
e.
Select one of the following options for System Capacity Selection.
–
SIP Extension Type
–
IP-Extension Type
–
System Resource Type
f.
Click the IP Extension Setting button on the Master site to configure an IP extension. For details, refer
to the following instructions.
Note
•
You cannot configure IP extensions for Slave units.
•
The following items can be configured. Click OK when you have finished.
<IP Extension Setting>
Specify a number for each category in Number of IP Extensions
–
IP-PT for V-IPEXT32
–
UT/UDT for V-UTEXT32
–
SIP-Phone for V-SIPEXT32
g.
Click the SIP Trunk Setting button on the master site to configure a SIP CO line. For details, refer to
the following instructions.
Note
•
You cannot configure SIP CO lines for Slave units.
•
The following items can be configured. Click OK when you have finished.
<SIP Trunk Setting>
Configure the following items for 1st Account Setting / 2nd Account Setting
–
Number of SIP Trunk
–
User Name (64 characters)
–
Authentication ID (64 characters)
–
Authentication Password (32 characters)
–
SIP Server Name / Outbound Proxy Name ( Max.100 characters)
–
SIP Server IP Address
–
SIP Server Domain / Proxy Domain ( Max.100 characters)
h.
Click Next.
Note
•
The value you select for Default value of Numbering Plan affects the default values for certain
settings, such as floating extension numbers, and has a large effect on the system. Select this
value with care. For details about the default values that are affected, refer to step 3 in this
procedure.
•
The value you select for System Capacity Selection determines the maximum numbers of virtual
CO line slots and virtual extension slots, and has a large effect on the system. Select this value
Document Version 2016-03
3 digits
4 digits
Extension
Extension
Number
Number
500–507
5000–5015
536–599
5801–5864
600
6000
601–664
6001–6064
508, 509
5101, 5102
510
5103
5.4.1 Easy Setup Wizard
Installation Manual