4.3.1 Mother Board
LED Indications
Indication
STATUS
BATT ALARM
MASTER
130
Installation Manual
Color
Description
Green
PBX status indication
•
OFF: Power Off
•
ON: Power On and running
•
Flashing: Starting up/Logging in
Amber
PBX status indication
•
ON: Ready to shutdown
•
Flashing: Shutting down
Red
PBX status indication
•
ON: Alarm
The cause may be one of the following:
–
Power was cut without performing the
shutdown procedure.
–
No IP address(es) assigned for the DSP
card(s) by the DHCP server.
–
Alarm for an optional service card.
•
Flashing (240/minute): Initialize failed
•
Flashing (60/minute): WAN connection session
malfunction (router malfunction)
For more information, refer to "8.6.2 WAN
Connection".
Red
Alarm indication
•
OFF: Normal
•
ON: Alarm
Green
Master unit status indication
•
ON: Master
Slave unit status indication
•
Flashing: Running as Backup Master unit
Amber
Master unit status indication
•
Flashing: Factory default
Slave unit status indication
•
ON: Slave
•
Flashing: Factory default/Starting up
Red
Master unit status indication
•
ON: Recovered (Waiting to be switched with
Backup Master unit)
Slave unit status indication
•
Flashing: Isolated from Master unit
Document Version 2016-03