4.3.1 Mother Board
LED Indications
Indication
STATUS
BATT ALARM
MASTER
130
Installation Manual
Color
Description
Green
PBX status indication
OFF: Power Off
ON: Power On and running
Flashing: Starting up/Logging in
Amber
PBX status indication
ON: Ready to shutdown
Flashing: Shutting down
Red
PBX status indication
ON: Alarm
The cause may be one of the following:
Power was cut without performing the
shutdown procedure.
No IP address(es) assigned for the DSP
card(s) by the DHCP server.
Alarm for an optional service card.
Flashing (240/minute): Initialize failed
Flashing (60/minute): WAN connection session
malfunction (router malfunction)
For more information, refer to "8.6.2 WAN
Connection".
Red
Alarm indication
OFF: Normal
ON: Alarm
Green
Master unit status indication
ON: Master
Slave unit status indication
Flashing: Running as Backup Master unit
Amber
Master unit status indication
Flashing: Factory default
Slave unit status indication
ON: Slave
Flashing: Factory default/Starting up
Red
Master unit status indication
ON: Recovered (Waiting to be switched with
Backup Master unit)
Slave unit status indication
Flashing: Isolated from Master unit
Document Version 2016-03