5.3 Starting Web Maintenance Console
•
Data conversion does not support system data from KX-TDA series PBXs. To convert KX-TDA data,
first convert it to KX-TDE data using the PBX Replacement of Unified Maintenance Console and then
convert that data to KX-NS1000 data.
•
Data for cards that are supported in legacy gateways connected to the KX-NS1000 can be converted
from KX-TDE series and KX-NCP series PBXs.
•
Data for IP-EXT16 cards in a KX-TDE series or KX-NCP series PBX will be converted for use with a
V-IPEXT32 card in the KX-NS1000. IP-PTs that had been connected to the IP-EXT16 card must be
registered again to the V-IPEXT32 card in the KX-NS1000.
•
PBX voice data (e.g., ESVM, SVM, OGM) is not converted.
•
Data conversion for a SLC/LCOT card in the KX-NS1000 is not supported; the number of ports in these
cards is too small.
•
After conversion, if CSs are connected to both Slave units and the Master unit, you must change the
settings so that all CSs are connected to the Master Unit.
•
Data that is not supported by the data conversion is shown in the following table.
Unsupported Item
Time Mode
Current time mode
Time mode switching time (manual mode)
Wired/Wireless extensions
Timed Reminder
Station Lock
Remote Station Lock
Extension Call Charge Total
Not Ready/Ready (Wrap-up)
LCS On/Off
Room Status (Check In/Check out/Not Ready/
Cleaned Up)
Auto Answer
Absent Message Status
Saved Number Redial
ICD Group Login Status (Login/Logout)
Message Waiting
Incoming Log
Outgoing Log
TAM Log
Personal Absent Message
182
Installation Manual
Default Setting
Location setting default
Not Stored
Not set
Unlocked
Unlocked
Total cleared
Wrap-up status cleared
Location setting default
Location setting default
Location setting default
Not set
Number cleared
Location setting default
Canceled
Cleared
Cleared
Cleared
Message cleared
Document Version 2016-03