Alarm
Message
Type
PE n: Loss of
Clear
Input
Digital Program
Set
Mapping
Digital Program
Set
Mapping
Digital Program
Set
Mapping
Message
Cause/Remedy
Fault reset
PID Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
Program Collision
Cause: Uplink
settings may have
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
Mode-i PMT out of
Cause: Uplink
settings may have
range
changed since
setting up the unit.
Please check your
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink to
find the
appropriate system
settings.
Description
Severity
Minor
Two source
Minor
service PIDs
are being
mapped to the
same output
PID. This will
cause data
corruption in
the stream.
Two source
Minor
channel
numbers are
being
mapped/
passed to the
same channel
number in the
output.
PMT PID to be
Major
used for
Mode-i is
outside of
valid MPEG
PID range.
ID
11000
12000
13000
14000
15000
16000
17000
18000
18009-18032
19000
19000
19000
281