3
Remove the plastic washer (B).
4
Remove the MPF pick roll assembly.
Installation warning: When replacing the MPF pick roll assembly, do not touch the rubber surface.
MPF tray door assembly removal (models X651, X652, X654, X656)
1
Open the MPF tray door.
2
Carefully pry the left and right manual feeder tabs out of the slots in the manual feed tray.
3
Rotate the manual feeder vertical and pull straight up to remove the feeder.
Repair information
340