Xerox phaser 3635 Service Manual page 95

Hide thumbs Also See for phaser 3635:
Table of Contents

Advertisement

1
Disconnect the harness at the left end.
Figure 2 Left harness disconnection
4.
Carefully remove the heat lamp from the fuser assembly by withdrawing it through the
right end of the fuser, Figure 3.
Draft 4
Phaser 3635MFP
2
Remove the fixing screw.
Replacement
1.
4-35
Heat lamp
Figure 3 Heat lamp removal
Replacement is the reverse of the removal procedure.