Input terminal state monitor (R144 )
It indicates the states of the control terminals No. 1 to 7 and phase A and B of the encoder input.
Relay No.
R1440
OPEN signal input state
R1441
CLOSE signal input state
R1442
OPEN arrival signal input state
R1443
CLOSE arrival signal input state
R1444
Safety sensor signal input state
R1445
OPEN speed change input state
R1446
CLOSE speed change input state
R1447
Encoder phase A signal input state
R1448
Encoder phase B signal input state
Output terminal state monitor(R145 )
It indicates the output states of RY output terminal.
Relay No.
R1450
RY1 output signal
R1451
RY2 output signal
R1452
RY3 output signal
Operation status monitor(R146 )
It indicates the operation status of the inverter.
Relay No.
R1460
Run signal (RUN)
R1461
Reverse run signal (REV)
R1462
Arrival signal(FR-ARV)
R1463
Overload alarm (OL)
R1464
OPEN arrival signal (OP-ARV)
R1465
CLOSE arrival signal (CL-ARV)
R1466
Obstacle detection signal
R146F
Fault alarm
Name
1: Terminal is ON (closed).
0: Terminal is OFF (opened).
Name
1: RY output signal is ON (energized).
0: RY output signal is OFF (not energized).
Name
1: Runs
0: Stops
1: Reverse operation runs.
0: Stops or forward operation runs.
1: It is turned ON.
0: It is turned OFF.
1: Fault state
0: Normal state