Door position area (n07)

Indicates the operation area of the door position.
[0]: CLOSE hold operation area, [1 to 6]: OPEN operation area
[7]: OPEN hold operation area,

Door position (n08)

Indicates the data value of the door position. (Data range: 1 to 65535)
Operation panel display: Displays as 1
Monitor by communication function: Directly displays the door position data.

OPEN arrival position data (n09)

Indicates the data value of the door position while the OPEN arrival signal is
changing from OFF to ON.
Operation panel display: Displays as 1
Monitor by communication function: Directly displays the door position data.

No. of door switching (n10)

Number of switching can be monitored up to 65,535 times.
Operation panel display: Displays as 1 time
Monitor by communication function: Directly displays the number of switching.
The data of the number of switching can be cleared by setting the parameter
P42 (setting data clear) to "2".
Encoder detection status (n11)
Indicates the pulse frequency of the encoder signal.
Also indicates the rotation direction of the motor by the encoder signal.
F: Forward run (OPEN operation), r: Reverse run (CLOSE operation)
Note) In the non-encoder mode (Parameter P09 = [1, 2, 3]), the encoder detection status
(n11) cannot be detected. The panel display will be "0.0".
Control terminal status (Input signal/output signal) (n16 and n17)
The statuses of the input and output signals of the control circuit terminal
can be monitored by "Lightening/Lightening out of each LED segment".
32
[8 to 13]: CLOSE operation area
"0.01" and 10,000
[0.01] and 10,000
"0.01" and 10,000 times
"100.".
[100.].
[100.].