1St Acceleration Time (Parameter P01); 1St Deceleration Time (Parameter P02); V/F Pattern (Parameter P03); Functional Descriptions (By Parameters) 41 - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Functional Descriptions (By parameters)

1st ACCELERATION TIME (Parameter P01)

Used to set the time to accelerate to the maximum
output frequency from 0.5Hz.
Data setting range (s)
Setting unit (s)
The display code for 0.04s is "000".
The maximum output frequency is set with parameters
P03 and P14.

1st DECELERATION TIME (Parameter P02)

Used to set the time to decelerate from the maximum
output frequency to 0.5Hz.
Data setting range (s) 0.04
Setting unit (s)
The display code for 0.04s is "000".
The maximum output frequency is set with parameters
P03 and P14.

V/F PATTERN (Parameter P03)

A frequency range of 50/60Hz or 50 to 250Hz can be set independently from
the maximum output frequency (50 to 250 Hz).
Data setting
Name
value
5 0
50Hz mode
6 0
60Hz mode
Free mode
F F
[50Hz mode]
Max. output frequency=50Hz
Base frequency=50Hz
100
0
Output frequency 50(Hz)
Note1) Both the maximum output frequency and base frequency are set to 50Hz as the
factory setting data.
Note2) Take note to the upper frequency clamp (parameter P29) when changing the
maximum output frequency setting.
0.04
0.1
999
0.1 0.1
100 1 100
0.1 to 999
0.1 0.1 to100 1 100 to 999
The V/F pattern is set regardless of the parameter
P14 and P15.
The V/F pattern is set according to the parameter P14 and
P15. The maximum output frequency is set in parameter
P14 and base frequency is set in parameter P15.
[60Hz mode]
Max. output frequency=60Hz
Base frequency=60Hz
100
0
Output frequency 60(Hz)
999
Remarks
[Free mode]
100
0
Output frequency(Hz)
Max. output
frequency
0.5
Acceleration
time
Max. output
frequency
0.5
Deceleration
time
Max. output frequency
(P14)
Base frequency(P15)
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents