Details and cause of fault
Display
En1
There is no encoder pulse
The rotation direction of the encoder
En2
pulse is different from the rotation
direction of a command
OPEN arrival signal and CLOSE
En3
arrival signal are both turned ON.
When door position data is OPEN arrival
En4
state, there is no arrival signal.
When door position data is CLOSE arrival
En5
state, there is no arrival signal.
CPU
Excessive noise applied on the inverter
Note) Refer to " Troubleshooting
Caution
Depending on the start mode function setting, if the fault trip is reset
with inputting the run signal, the inverter may restart suddenly.
(Reset the trip after ensuring personal safety.)
Failure to do so could lead to injury.
If a fault is displayed on the operation panel's main display and the inverter is
stopped, remedy the fault before resetting. It is possible to restart the inverter
after resetting.
Power
Turn OFF the power once, then turn it ON again.
reset
(Operation can be started when the power is turned ON again.)
When operation is set to local (Parameter P08 set to "0" or "1"), the fault
will be reset when the "STOP button" on the operation panel is pressed.
Resetting
When operation is set to external ( Parameter P08 set to "2"), the fault
by stop
will be reset when both the OPEN/CLOSE signal are turned OFF.
signal
When operation is set to communication ( Parameter P08 set to "3"),
the fault will not be reset even if the operation command of communication
is turned OFF. In case of communication setting, the fault will be reset with
"fault reset command".
Resetting
The fault will be reset when the "STOP button" on the operation panel
by panel
is pressed.
90
and

Resetting Fault Trips

Remedies
Check the encoder's power supply
Check the encoder's wiring
Check the encoder's wiring
(phase A and phase B)
Check the OPEN arrival signal and
CLOSE arrival signal
Check the OPEN arrival signal.
Check the CLOSE arrival signal
Reduce the noise around the inverter.
" on page 91 and 92.