Supplementary Explanation Of Door Width Measurement - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Supplementary Explanation of Door width Measurement

NOTE
!
When the door width is being measured, the operation direction of
the door may change automatically.
Start the operation after ensuring personal safety.
Failure to do so could lead to injury.
Depending on start mode setting, if reset the door width measurement
by inputting the run signal, the inverter may restart suddenly.
(Start the operation after ensuring personal safety.)
Failure to do so could lead to injury.
The door width measurement is the function that measure the door
width according to the encoder signal and save the measurement
value to parameter d01 automatically. Measure the door width according
to the following operation conditions.
[Operation conditions]
1. Set parameter P09 to "3".
2. Change the run signal to ON.
(Set the run signal according to the operation command of parameter P08.)
3. Start operation towards OFF direction.
( In the course of door width measurement, "CAL" is displayed on panel.)
4. When the CLOSE arrival position is detected, it changes to ON direction.
5. Once the OPEN arrival position is detected, the door width measurement is over.
( When the door width measurement is over, "End" is displayed on panel.)
6. If change the run signal to OFF, the "End" display is reset.
(The setting data value of parameter P09 changes to "1" automatically.)
7. The measurement value of the door width is saved in parameter d01 automatically.
8. Used to set operation frequency of the door width measurement with parameter d52.
( The measurement frequency of the door width must be used with low speed.)
Note1) When the door width is being measured, start the operation after ensuring
that there is no obstacle on the way.
If there is obstacle on the way, the position where the obstacle is located is
determined to be the arrival position. So the measurement cannot be made correctly.
Note2) Set the encoder constant of parameter P52 correctly.