Operation Command Select (Parameter P08); Panel Reset Function; Panel Stop Function - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

[ParameterP06 1
100
Boost
level
0
Output frequency (Hz)
OPERATION COMMAND SELECT(Parameter P08)
Used to select whether to carry out start/stop and forward/reverse with the
operation panel (panel), with signals input from external devices or with
communication command.
Data
Panel
setting
external
value
control
function
0
Panel Provided
1
External
2
Provided
control
Comm-
3
Provided
unication
! Caution:
Depending on the start mode function setting, if the fault trip is reset
or the stop state is released with panel STOP function" with run signal
being input, the inverter may restart suddenly.
(Perform the operation after ensuring personal safety.)
Failure to do so could lead to injury.

Panel reset function

When a fault trip occurs, the state can be reset with the "STOP button" on the operation panel.
(This function is called" Panel reset function".)

Panel STOP function

When setting external control (Parameter P08="2"), the operation may stop with
"STOP button" on operation panel. At this time, the panel displays "
(This function is called as "Panel STOP function".)
When the panel displays "
In this case , if the operation signal of control terminal is ON, the inverter begins to
carry out operation.
100
90
Boost
60
level
50
0
Output frequency (Hz)
Panel
reset
Operation method and control terminal connection diagram
Start: RUN, Stop: STOP, Forward/reverse: set in dr mode
Forward run:
1
2
8
Make the operation command input by communication valid.
[ParameterP06 2
25
50
RUN, Reverse run:
OPEN signal (ON: Forward /OFF: Stop)
CLOSE signal (ON: Reverse /OFF: Stop)
Common terminal
", repress "STOP button" to release the stop state.
[ParameterP06 3
100
Boost
60
level
15
0
Output frequency (Hz)
RUN, Stop: STOP
50
" .
43