SETTING DATA CLEAR(Parameter P42)
The set data can be changed to the factory setting data in a batch.
Also, the data of the monitor mode n10(No. of door switching) can be cleared.
Data setting
value
0
Data value that indicates normal state.
1
Changes all data to the factory settings.
Data of the monitor mode n10(
2
is cleared to "0". (Other data will not be changed.)
Modify function assignment of self-defining mode to be
3
ex-factory setting state.
Note) Press SET button when the display value changes to "1" or "2" , then the data
will be cleared. The set data will return to "0" automatically.

INPUT SIGNAL LOGIC SETTING (Parameter P43)

It can be selected to detect the input signal by "A contact input" or "B contact input".
Data setting range 0

Setting value

A contact input="0": When SW(switch) signal is closed (terminal level is "L"), ON is detected.
B contact input="1": When SW(switch) signal is opened (terminal level is "H"), ON is detected.

Setting method

Convert 0 to 4 bits to decimal numbers and input.
Input the total value of the setting value the additional value for the setting data.
(Example) When CLOSE speed change signal (4bits) and OPEN speed
change signal (3bits) is B contact input.
Setting data=(1 16) (1 8) (0 4) (0 2) (0 1) 24
Signal
name
Terminal No.
bit
Setting value
Additional value
Note) The logics of the OPEN signal and CLOSE signal cannot be changed. "A contact
input" is a fixed value.
Details
to
31
4bit
3bit
CLOSE
OPEN
speed change
speed change
7
6
3
4
0/1
0/1
16
8
No. of door switching
2bit
1bit
0bit
Safety
CLOSE
sensor
Arrival
5
4
2
1
0/1
0/1
4
2
)
OPEN
Arrival
3
0
0/1
1
55