Always confirm the security and function operation of the elevator
before obstacle detection function is applied.
Failure to do so could lead to injury.
Make sure to input safety sensor in the main controller of the elevator
and to operate the door's obstacle detection on the main controller side.
Obstacle detection function of the inverter does not operate in
CLOSE arrival area.
Always take dual security measures.
Failure to do so could lead to injury.
Make sure to input arrival signal (limit switch etc.)in the main controller
of the elevator and to operate the door's obstacle detection on the
main controller side.
Do not operate obstacle detection of the door only with OPEN/
CLOSE arrival signal (input signal and the relay's output signal).
Failure to do so could lead to injury.
Depending on different settings of the fault OPEN operation forced
operation time and the stop selection of OPEN/CLOSE operation,
sometimes even OPEN/ CLOSE signal are both turned OFF, the door
does not stop.
Confirm the elevator's security and function operation before using
this equipment.
(Secure personal safety before carrying out the operation.)
Failure to do so could lead to injury.
Depending on settings of the start mode and ride-through function
settings, if the run signal is ON or the power is restored after a power
failure, the inverter may start (restart) suddenly. Keep out of the working
part of the motor and the machine.
Design the machine so that personal safety can
be ensured even if the inverter starts suddenly.
Failure to so could lead to injury.
Depending on the start mode function setting, if "the fault trip is reset"
or "the stop state is released with the panel STOP function" or
"door width measurement is reset" when the run signal is input,
the inverter may restart suddenly.
(Secure personal safety before using this function.)
Failure to do so could lead to injury.
When the retry function is used, the inverter may automatically start(restart)
suddenly. Keep out of the working part of the motor and the machine.
(Secure personal safety before using this function.)
Failure to so could lead to injury.