Fault CLOSE operation frequency (Parameter d54 d59)

Fault CLOSE operation acceleration /deceleration time (Parameter d60 d65)
Frequency and acceleration/deceleration time in fault CLOSE operation
accord to setting value of d54 to d59: fault CLOSE operation frequency
1 to 6 and d60 to 65: fault CLOSE operation acceleration/deceleration
time 1 to 6.
Setting data of d60 to d65 are effective only when Parameter P80:
safety sensor function select is set to be 1 or 2.
Speed change position and hold operation in fault CLOSE operation
may use parameters for normal CLOSE operation.
In the event that setting value of fault CLOSE operation frequency is
more than CLOSE frequency, when CLOSE operation becomes fault
CLOSE operation, speed may rise sharply. Therefore, data should be
set to be less than CLOSE frequency.
In the event that setting value of fault CLOSE operation acceleration/
deceleration time is more than CLOSE acceleration/deceleration time,
when CLOSE operation becomes fault CLOSE operation, acceleration/
deceleration time may change sharply according to setting. Therefore,
notice is required to be taken while setting data.