Panasonic AAD03011 Instruction Manual page 98

Elevator door controller
Table of Contents

Advertisement

Regenerative
braking torque
DC braking
Start/stop
Frequency setting signal
Door operation mode setting
Door control function
Accel./decel. time
Accel./decel. characteristics Linear and S-shaped characteristics (selection changeover)
Stop mode
Stop frequency
Reset function
Skip frequency setting
Upper frequency clamp setting Optional setting from 0.5 to 250Hz.
Lower frequency clamp setting Optional setting from 0.5 to 250Hz.
Ride-through function
Retry function
96
With
100% or more (Short-time)
brakes
Without
80% or more
brakes
Operates when less than stop frequency
Braking torque level: 0 to 100 (set between 20 levels)
Braking time: Optional setting for 0.1 to 120s
Operation panel buttons
Control terminal input signal (OPEN signal, CLOSE signal)
Communication command (RS485)
Operation panel setting
Door operation mode setting
Communication command (RS485)
OPEN/CLOSE operation frequency: Max.6 speed can be set.
Accel./decel. time: Set OPEN and CLOSE operation frequency respectively.
Door speed change position: Up to 5 place settings
Door hold frequency: 1 speed (individual OPEN and CLOSE setting)
Door hold torque: Hold current setting ( individual OPEN and CLOSE setting)
Door speed control in encoder mode
Door speed control in SW (switch) mode.
Door width measurement function
Door obstacle detection function
0.04 to 999s (individual acceleration and deceleration setting)
Select from ramp-to-stop or coast-to-stop (selection changeover)
Optional setting from 0.5 to 60Hz.
Stop signal reset, panel reset and power supply reset.
Up to 3 place settings
(skip frequency band setting from 1 to 10Hz)
Validity of function, and 0Hz restart, operating frequency
restart (selection changeover)
Retry selection : Select validity of function and details of retry fault
Retry times: Optional setting for 1 to 10 times