Input signal
Output signal
Communication function
Built-in power supply
Operation and control
status
Fault details
Current limit
Trip (stop)
Stall prevention function
Working ambient
temperature and humidity
Transportation and storage
temperature and humidity
Vibration
Altitude
Atmosphere medium
Enclosure
Cooling method
OPEN/CLOSE signal: 1a contact signal
OPEN/CLOSE arrival signal: 1a or 1b contact signal (selection changeover)
Safety sensor : 1a or 1b contact signal (selection changeover)
OPEN/CLOSE speed change signal: 1a or 1b contact signal (selection changeover)
Door position detection signal: encoder signal (2-phase input)
Relay output: 3 outputs, 1c contact
(contact capacity 230V AC, 0.3 A, 30 V DC, 0.3 A resistance load)
Output function: Run signal, reverse run signal, arrival signal,
overload alarm, OPEN arrival signal, CLOSE arrival signal,
obstacle detection, fault warning (seletable)
Interface: RS485 serial communication
Communication speed:4800/9600/19200 bps (selectable)
Protocol: MEWTOCOL-COM
Communication method: Half duplex
Max. No. of connected units: 31 units
Max. transmission distance: 500m (total length)
12 V DC -10 %/ 20 %, 0.1 A or less
(exclusive for encoder)
Output frequency, output current, output voltage, internal
DC voltage, setting frequency, detection frequency, door
position area, door position, OPEN arrival position data,
No. of door switching, encoder detection status, control
terminal status (input signal, output signal)
Symbol indicated when protective function activates (last 4 faults are stored.)
Current limit can be set from 1 to 200% of rated output current.
Instantaneous overcurrent, temperature error (SC1 to 3) ,
overcurrent (OC1 to3), overload/electronic thermal overload(OL),
low voltage (LU), overvoltage (OU1 to 3), auxiliary fault (AU),
operation error(OP), encoder error (En1,2), arrival signal error
(En3 to 5)
Overcurrent stall prevention, overvoltage stall prevention
-10 to +50 (with no freezing)
90% RH or less(25
-25 to +65
95% RH or less(25
5.9m/s
2
{0.6G} or less
1000m or less
Indoors, with no corrosive gases, explosive gases, oil mist or dust present
IP20 defilable type, however, excluding incoming line
holes of main circuit line and control line.
Self-cooling
with no dew condensation)
with no dew condensation)
97