4.2.2 Configuration Data Setting Items

 Count function (Settable for each channel)
item
Counter type
Enable/Disable
overflow/underflow
Counter upper limit
Counter lower limit
Count direction
Count input
selection
Count method
Input Z signal
function setting
Control 0 signal
function setting
Control 1 signal
function setting
Comparison match
leading edge reset
Comparison match
trailing edge reset
Default value
Preset value
Current value
changed value
next page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Linear counter/Ring counter
Disable/Enable
-2,147,483,647 to 2,147,483,647
-2,147,483,648 to 2,147,483,646
Normal direction/Reverse direction
Count signal
Internal clock 0.25 us (4 MHz)
Internal clock 1.00 us (1 MHz)
Internal clock 10 us (100 kHz)
Internal clock 100 us (10 kHz)
2-phase input 1 multiple, 2-phase input 2 multiple,
2-phase input 4 multiple, Individual input 1 multiple, Individual input
2 multiple,
Direction detection input 1 multiple,
Direction detection input 2 multiple
Not used
Reset operation at rising edge
Reset operation at trailing edge
Positive logic reset operation
Negative logic reset operation
Preset operation at rising edge
Preset operation at trailing edge
Positive logic preset operation
Negative logic preset operation
Not used
Positive logic enable operation
Negative logic enable operation
Positive logic enable operation and reset operation at rising edge
Negative logic enable operation and reset operation at trailing edge
Positive logic enable operation and preset operation at rising edge
Negative logic enable operation and preset operation at trailing
edge
Not used
Positive logic enable operation
Negative logic enable operation
Specify the comparison match flag used as a reset signal for
resetting count values at the rising edge of comparison match flag.
Specify the comparison match flag used as a reset signal for
resetting count values at the trailing edge of comparison match flag.
Set the count value when the power is turned on.
-2,147,483,648 to 2,147,483,647
Set the count value for the preset operation.
-2,147,483,648 to 2,147,483,647
Set the current value changed value to change the count value.
-2,147,483,648 to 2,147,483,647
Description
Default
Linear counter
Disable
2,147,483,647
-2,147,483,648
Normal direction
Count signal
2-phase input 1
multiple
Not used
Not used
Not used
Not reset
Not reset
0
0
0