Sensor warm-up acceleration
There is a function available for accelerating the warm-up procedure for selected EC
sensors. The function shortens the time taken until the unit is ready to make measure-
ments, i.e. the time taken to save the display and alarm evaluation of the measure-
ments. The time to activate the calibration is not changed.
•
In order to use the sensor warm-up acceleration function in the Dräger X-am 5000,
at least one sensor suitable for the purpose must be fitted and registered in the unit
using the Dräger CC-Vision PC software.
•
After that, activate the function by ticking the "Accelerated warm-up" checkbox ("De-
vice" menu) and updating the device data with Dräger CC-Vision.
A selection menu for activating the process will only be displayed after the device is
restarted by plugging in a power pack.
•
Restart the device by plugging in a
power pack.
−
All the display segments, including the
visual, audible and vibration alarms,
are activated for a short time.
−
The software version is displayed.
−
The instrument performs a self test.
−
The sensor warm-up acceleration
menu is displayed.
The steps in the selection menu are li-
mited by a 25-second time-out, which
then changes to the standard setting
of unaccelerated warm-up and pro-
ceeds with the device start-up proce-
dure.
•
It is necessary to select between two
times for the sensor warm-up accele-
ration,
— the shortened time achievable as a re-
sult of the warm-up acceleration,
— the unshortened time required by the
installed sensors to save the measure-
ment display (measurement does not
flash any more).
•
Select the shortened warm-up time
with the
button and confirm it with
the
button.
OK
−
The function for entering the password
is called up.
•
Enter the digits with the
confirm with the
NOTICE
button and
button.
OK
Sensor warm-up acceleration
5:00
120:00
001
51