Dräger X-am 2500 Instructions For Use Manual
Hide thumbs Also See for X-am 2500:

Advertisement

Gebrauchsanweisung
de
3
Instructions for Use
en
16
Notice d'utilisation
fr
29
Instrucciones de uso
es
43
Instruções de uso
pt
56
Istruzioni per l'uso
it
69
Gebruiksaanwijzing
nl
83
Brugsanvisning
da
96
®
Dräger X-am
(MQG 0011)
i
Käyttöohjeet
fi
109
Bruksanvisning
no
122
Bruksanvisning
sv
135
Instrukcja obs ugi
pl
148
ru
162
Upute za uporabu
hr
176
Navodilo za uporabo
sl
189
Návod na použitie
sk
202
2500
Návod na použití
cs
215
bg
228
Instruc iuni de utilizare
ro
241
Használati útmutató
hu
254
el
267
Kullanma talimatlar
tr
282
zh
295

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X-am 2500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dräger X-am 2500

  • Page 1 Gebrauchsanweisung Käyttöohjeet Návod na použití Instructions for Use Bruksanvisning Notice d’utilisation Bruksanvisning Instruc iuni de utilizare Instrucciones de uso Instrukcja obs ugi Használati útmutató Instruções de uso Istruzioni per l'uso Upute za uporabu Kullanma talimatlar Gebruiksaanwijzing Navodilo za uporabo Brugsanvisning Návod na použitie ®...
  • Page 3: For Your Safety

    Safe coupling with electrical devices NOTICE Electrical connections to devices which are not listed in these Instructions Indicates additional information on how to use the product. for Use should only be made following consultation with the respective manufacturers or an expert. Dräger X-am 2500...
  • Page 4: Product Overview

    Display 14 Special symbols or dusts of groups A, B, C, D or E, F, G, and temperature class T3 or T4 (depending on the batteries and rechargeable battery) may 15 Tool for sensor change be present. Dräger X-am 2500...
  • Page 5: Preparations For Operation

    Dräger. Different settings can be selected to meet customer requirements on delivery. The current setting can be checked and changed with the Dräger CC Vision software. Only when activated in the instrument configuration. Delivery condition: not activated. Dräger X-am 2500...
  • Page 6: Switching Off The Instrument

    In the event of an impact load when using a CatEx sensor in the Dräger X-am 2500 that causes the fresh air display to In case of measurements in oxygen-deficient atmosphere deviate from zero, the zero point and sensitivity must be (<8 vol.
  • Page 7: Identifying Alarms

    A1 = lack of oxygen 4.6.5 Battery main alarm A2 = excess oxygen Intermittent alarm: After leaving the area, when the concentration has dropped below the alarm threshold: Flashing special symbol on the right side of the display: Dräger X-am 2500...
  • Page 8: Info Mode

    Press the [+]-key when the instrument is turned off. The name of the gas, measuring unit, and measuring range limit value are displayed for all channels. Press the [+]-key again to exit the Info Off Mode (or via timeout). Dräger X-am 2500...
  • Page 9: Common User Tasks

    For battery holder (order no. 83 22 237): replace alkaline batteries or three complete charge/discharge cycles. Never store the instrument for respectively NiMH rechargeable batteries. Ensure correct polarity. extended periods without being connected to a power source (maximum of 2 months) because the internal buffer battery will drain. Dräger X-am 2500...
  • Page 10 Have the instrument calibrated by the service personnel. selected sensor is set to the value of the test gas used. Use a standard test gas. Upon application of the Dräger mixed gas (order no. 68 11 130) the displays should be within this range. Dräger X-am 2500...
  • Page 11 The measurement value flashes. For the adjustment of the ex-channel to the measuring gas methane, the display of the instrument must be set to a value of 5 % (relative) higher than the test gas concentration used. Dräger X-am 2500...
  • Page 12: Maintenance

    Collect batteries and rechargeable batteries as specified by Abrasive cleaning tools (brushes etc.), cleaning agents and the applicable regulations and dispose of at battery collection cleaning solvents can destroy the dust and water filters. centres. Carefully dry the instrument with a cloth. Dräger X-am 2500...
  • Page 13: Technical Data

    220 to 250 g The Technical Handbook and Instructions for Use/data sheets for the utilized sensors and the PC software CC-Vision for Dräger X-am 2500 can be downloaded on the product page of the X-am 2500 at the following Internet address: www.draeger.com Not subject to BVS10 ATEX E 080X and PFG 10 G 001X performance approval.
  • Page 14 EN 50271 The Technical Handbook and Instructions for Use/data sheets for the utilized sensors and the PC software CC-Vision for Dräger X-am 2500 can be downloaded on the product page of the X-am 2500 at the following Internet address: www.draeger.com For decreasing concentrations, the adjustment time for nonane is about 50 seconds.
  • Page 15 Effect of sensor poisons – – – – – – Hydrogen sulphide H S, 10 ppm Hydrogen sulphides, heavy metals, silicone-, sulphur- and polymerization-capable materials ≤±2 % of the measuring ≤±2 % of the measuring Linearity error value value Dräger X-am 2500...
  • Page 16: Notes On Approval

    D = 2012, E = 2013, F = 2014, H = 2015, J = 2016, K = 2017, L = 2018 etc. Example: Serial No. AREH-0054: the third letter is E, which means that the Not subject to BVS10 ATEX E 080X and PFG 10 G 001X performance ap- unit was manufactured 2013. proval. Dräger X-am 2500...
  • Page 17: Instructions For Safety

    Use only battery packs type ABT 01xx, HBT 00xx or HBT 01xx. See marking on battery pack for approved batteries and related Temperature Code. Not tested in oxygen enriched atmospheres (>21 % O High off scale readings may indicate an explosive concentra- tion. Dräger X-am 2500...
  • Page 18: Declaration Of Conformity

    Notes on approval Declaration of conformity Dräger X-am 2500...
  • Page 20 Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany 90 33 365 - GA 4638.205 +49 451 882-0 © Dräger Safety AG & Co. KGaA Fax +49 451 882-20 80 Edition 02 - February 2013 (Edition 01 - September 2012) www.draeger.com Subject to alteration...

This manual is also suitable for:

Mqg 0011

Table of Contents

Save PDF