Available languages

Maximum Setpoint Speed
Jog-Drehzahl
Jogging Speed
Defines the maximum output speed of the servo controller.
In case the preset speed is too high the value is limited
internally to the maximum permissible value!
Presetting of speed that can be activated via digital inputs I1 or I2.
Depending on the assignment of the inputs the jogging speed can be
activated by direction of rotation "forward" or alternatively direction of
rotation "reverse" . If both directions of roation are preset at the same time then
rotation "forward" has priority.
Condition:
The control terminals X2.1(ST), X2.3 (F) or X2.4 (R) must be connected
with terminal X2.10 (+16V) .
Function:
• I1 or I2 active
• I1 and I2 not active
• In jogging operation the drive accelerates and decelerates
at the torque limt.
• Original direction of rotation, speed, acceleration time
and deceleration time are without function.
• In case the preset speed is too high the value is limited
internally to the maximum permissible motor speed!
Parameter Description
Setting range:
Resolution:
Factory setting:
Customer setting: ____
Setting range:
Resolution:
Factory setting:
Customer setting:
Drive runs with adjusted jogging speed.
Drive runs with original speed.
0...9999 rpm
0,5 rpm
GB
Rated speed
rpm
0...9999 rpm
0,5 rpm
100 rpm
_____rpm
GB 29