KEB COMBIVERT S4 Instruction Manual page 77

Hide thumbs Also See for COMBIVERT S4:
Table of Contents

Advertisement

Available languages

Available languages

Amplification Output A2
Calculation Example:
Switching Condition Out-
put D1
The analog output A2 (terminal X2.19) outputs the current speed of the
servo systems.
Parameter CP.20 defines the amplification of the analog output signal.
2)
1)
+10 V
- n
+n
-10 V
Standardization at amplification 1 (CP.20=1):
0...+/– 10 V ^ -6000...+6000 rpm
Rated speed of the servo system: 3000 rpm
At 1000 rpm a measurement shall be taken at analog output A2 +10 V.
value at amplification 1
CP.20 =
–––––––––––––––––––
desired value at +10V
6000 rpm
CP.20 = –––––––––––
1000 rpm
CP.20 =
6
Defines the switching condition of digital output D1.
! Refer to table Switching Conditions page GB 34 !
Parameter Description
Setting range:
Resolution:
Factory setting:
3)
Customer setting:
Characteristic 1: Amplification factor 1
Characteristic 2: Amplification factor 2
Characteristic 3: Amplification factor 0,5
Setting range:
Resolution:
Factory setting:
Remarks:
Customer setting:
-20...+20
0,01
+/– n
^ +/–10 V
Rated
______
0...20
1
20
ENTER–Parameter
______
GB 33
GB

Hide quick links: