Parameter Description
Function Output A1
GB
Amplification Output A1
Calculation Example:
GB 32
This parameter defines which variable is given out at analog output 1
(terminal X2.18).
Value Output variable
0
actual speed
1
apparent motor speed
2
actual torque
3
intermediate circuit voltage
4
speed reference variable
5
system deviation (speed control) -6000...+6000 rpm
6
setpoint torque
Parameter CP.19 defines the amplifcation of the analog output signal
at output A1 (terminal X2.18).
2)
+10 V
- n
-10 V
At 2000 rpm a measurement shall be taken at analog output A1 +10 V.
value at amplification 1 (s. CP.18) 6000 rpm
CP.19 =
desired value at + 10 V
Setting range:
Resolution:
Factory setting:
Remarks:
Customer setting:
Value range at CP.19=1
-6000...+6000 rpm
0...25 A
0...25 Nm
0...1000 V
-6000...+6000 rpm
0...25 Nm
Setting range:
1)
Resolution:
Factory setting:
3)
Customer setting:
+n,I,U,M
Characteristic 1: Amplification factor 1
Characteristic 2: Amplification factor 2
Characteristic 3: Amplification factor 0,5
0...6
ENTER-Parameter
________
^ -10V...+10V
^
0...+10V
^
0...+10V
^
0...+10V
^ -10V...+10V
^ -10V...+10V
^
0...+10V
-20...+20
0,01
3 x M
^ +10 V
Rated
_______
=
= 3
2000 rpm
1