Dsa Memory Isolation Test Results - IBM NeXtScale nx360 M4 Installation And Service Manual

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

Serviceable: No
Recoverable: No
Automatically notify Support: No
408-800-000
MLNX:MLNX_DiagnosticTestEthernetPort
Test Aborted
Explanation: Port Test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
408-801-000
MLNX:MLNX_DiagnosticTestIBPort Test
Aborted
Explanation: Port Test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
408-900-000
MLNX:MLNX_DiagnosticTestEthernetPort
Test Failed
Explanation: Port Test Failed.
Severity: Error

DSA memory isolation test results

The following messages can result when you run the memory isolation test.
201-000-000
Standalone Memory Test Passed
Explanation: Quick/Full Memory Test All CPUs
Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
201-000-001
Standalone Memory Test Passed
Explanation: Quick/Full Memory Test CPU 1 Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
201-000-002
Standalone Memory Test Passed
408-800-000 • 201-000-004
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under
test in the active state.
2. If these condition was met but the test keeps failing
the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
408-901-000
MLNX:MLNX_DiagnosticTestIBPort Test
Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under
test in the active state and a subnet manager
running on the fabric to which the port is attached.
2. If these condition was met but the test keeps failing
the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
Explanation: Quick/Full Memory Test CPU 2 Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
201-000-003
Standalone Memory Test Passed
Explanation: Quick/Full Memory Test CPU 3 Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
201-000-004
Standalone Memory Test Passed
Explanation: Quick/Full Memory Test CPU 4 Passed.
Severity: Event
Appendix C. DSA diagnostic test results