IBM NeXtScale nx360 M4 Installation And Service Manual page 241

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

80070228-2e01ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (IPMB IO Error)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: If the specified sensor is IPMB IO
Error, Me Error or ME Flash Error, complete the
following steps until the problem is solved:
1.
Restart IMM. If the error still appears, proceed step
2.
2.
Update the firmware (UEFI and IMM) to the latest
level. If the error still appears, proceed step 3.
3.
Replace the node.
80070301-0301ffff
Sensor [SensorElementName] has
transitioned to non-recoverable from a
less severe state. (CPU 1 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
5.
Make sure the PCI adapter is supported by the
server. To confirm, see the IBM ServerProven
website.
80070228-2e01ffff • 80070301-1101ffff
6.
Replace the PCI adapter and make sure the PCI
adapter is functioning normally.
80070301-0302ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
2.
Make sure the air baffles are placed and correctly
installed; and make sure the node cover is installed
and completely closed.
3.
Make sure the fans are operating, and there are no
obstructions to the airflow (both front and rear of
the server).
4.
Reduce the Ambient temperature. The system must
be operating within the specifications. (see Features
and specifications for more information)
5.
Make sure the PCI adapter is supported by the
server. To confirm, see the IBM ServerProven
website.
6.
Replace the PCI adapter and make sure the PCI
adapter is functioning normally.
80070301-1101ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure there is a node filler correctly installed
for the empty node slot.
Appendix A. Integrated Management Module II (IMM2) error messages