IBM NeXtScale nx360 M4 Installation And Service Manual page 267

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2008ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 8)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2581ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (All DIMMS)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
Severity: Info
806f040c-2008ffff • 806f0507-0301ffff
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f0413-2582ffff
Explanation: This message is for the use case when an
implementation has detected a PCI PERR.
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0232
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser cards.
3.
Update the server firmware (UEFI and IMM) and
adapter firmware. Important: Some cluster solutions
require specific code levels or coordinated code
updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for
the cluster solution before you update the code.
4.
Remove both adapters.
5.
Replace the PCIe adapters.
6.
Replace the riser card.
806f0507-0301ffff
Explanation: This message is for the use case when an
implementation has detected a Processor Configuration
Mismatch has occurred.
Severity: Error
Alert Category: Critical - CPU
Appendix A. Integrated Management Module II (IMM2) error messages
A PCI PERR has occurred on
system [ComputerSystemElementName].
(PCIs)
[ProcessorElementName] has a
Configuration Mismatch. (CPU 1)
249

Advertisement

Table of Contents
loading

Table of Contents