Dsa Memory Isolation Test Results - IBM System x3550 M4 Installation And Service Manual

Type 7914
Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

408-900-000 • 201-000-000
408-900-000
MLNX:MLNX_DiagnosticTestEthernetPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.
408-901-000
MLNX:MLNX_DiagnosticTestIBPort Test Failed
Explanation: Port Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Make sure that the physical link of the port under test in the active state and a subnet manager running on the
fabric to which the port is attached.
2. If these condition was met but the test keeps failing the port's adapter might be faulty.
3. Try replacing the adapter and repeating the test.

DSA memory isolation test results

The following messages can result when you run the memory isolation test.
201-000-000
Standalone Memory Test Passed
Explanation: Quick/Full Memory Test All CPUs Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
710
IBM System x3550 M4 Type 7914: Installation and Service Guide