Memory Test Error Codes - IBM eServer xSeries 455 Type 8855 Hardware Maintenance Manual And Troubleshooting Manual

Table of Contents

Advertisement

Code/explanation
9256-092-094-xxx, where xxx is 041, 045,
049, 053
(Deskew error.)
9256-092-094-xxx, where xxx is 042, 046,
050, 054
(Deskew error.)
9256-092-094-xxx, where xxx is 056-063
(Deskew error.)

Memory test error codes

Table 15. Memory test error codes
Error code/symptom
9301-Yxx-00-00 [Y=Failing node (1-4)]
(Test Aborted: Memory Hole Size Error.)
9302-Yxx-00-00 [Y=Failing node (1-4)]
(Test Aborted: DIMM Configuration Error.)
9303-Yxx-00-00 [Y=Failing node (1-4)]
(EFI operating system error. Test Aborted: Buffer too
small.)
9304-Yxx-00-00 [Y=Failing node (1-4)]
(EFI operating system error. Test Aborted: Invalid
Parameter.)
9305-Yxx-00-00 [Y=Failing node (1-4)]
(Test Aborted: Memory WRT not complete.)
9306-Yxx-00-00 [Y=Failing node (1-4)]
(Memory Diagnostic Program Error. Test Aborted: Invalid
Bank Selected.)
9307-Yxx-00-00 [Y=Failing node (1-4)]
(Test Aborted: Chipset Internal Error.)
9308-Yxx-00-00 [Y=Failing node (1-4)]
(Diagnostic Program Error. Test Aborted: No DIMMs
installed.)
9309-Yxx-00-00 [Y=Failing node (1-4)]
(Test Aborted: Fast Scrub Error.)
9310-Yxx-nn-nn [Y=Failing node (1-4)]
(Test Failed: ECC errors.)
nn= the DIMM connector designation, 1-28.
FRU/action
1. RXE cable A
2. RXE expansion board to which cable is connected (Side A or Side
B)
3. I/O board
1. RXE cable B
2. RXE expansion board to which cable is connected (Side A or Side
B)
3. Midplane board
1. Side A card in RXE100 (if xxx is 056, 057, 060, 061)
2. Side B card in RXE100 (if xxx is 058, 059, 062, 063)
FRU/action
1. Restart the server, and run the test again.
2. If the symptom still exists, then update the SAL/EFI.
1. Restart the server, and run the test again.
2. If the symptom still exists, then update the SAL/EFI.
1. Restart the server, and run the test again.
2. If the symptom still exists, update the SAL/EFI.
1. Restart the server, and run the test again.
2. If the symptom still exists, update the SAL/EFI.
1. Restart the server, and run the test again.
2. If the symptom still exists, replace the memory board.
1. Restart the server, and run the test again.
2. Reflash the diagnostic code.
3. If the symptom still exists, update the SAL/EFI.
1. Restart the server, and run the test again.
2. Reflash the diagnostic code.
3. If the symptom still exists, replace the memory board.
1. Restart the server, and run the test again.
2. If the symptom still exists, reflash the diagnostic code.
1. Restart the server, and run the test again.
2. If the symptom still exists, replace the memory board.
1. If nn's are 0, then run the memory test on all
banks.
2. Restart the server, and run the test again.
3. Replace DIMMs nn.
Chapter 6. Symptom-to-FRU index
193