Dsa Emulex Adapter Test Results - IBM NeXtScale nx360 M4 Installation And Service Manual

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

516-000-000 • 516-901-000
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.

DSA Emulex adapter test results

The following messages can result when you run the Emulex adapter test.
516-000-000
ELXUCNA: NIC MAC LoopBackTest
Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-001-000
ELXUCNA: NIC PHY LoopBackTest
Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-002-000
ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-800-000
ELXUCNA: NIC MAC LoopBackTest
Aborted
Explanation: Loopback testing at the MAC layer was
canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-801-000
ELXUCNA: NIC PHY LoopBackTest
Aborted
328
IBM NeXtScale nx360 M4 Type 5455: Installation and Service Guide
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Explanation: Loopback testing at the physical layer
was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-802-000
ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Aborted
Explanation: Verification of status LEDs was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
516-900-000
ELXUCNA: NIC MAC LoopBackTest
Failed
Explanation: A failure was detected during the
loopback test at the MAC layer.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
516-901-000
ELXUCNA: NIC PHY LoopBackTest
Failed
Explanation: A failure was detected during the
loopback test at the physical layer.