IBM NeXtScale nx360 M4 Installation And Service Manual page 305

Hide thumbs Also See for NeXtScale nx360 M4:
Table of Contents

Advertisement

816f0113-0301ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 1
PECI)
Explanation: This message is for the use case when an
implemenation has detected that a system has
recovered from a Bus Timeout.
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Installing the
system board). (n = microprocessor number)
816f0113-0302ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 2
PECI)
Explanation: This message is for the use case when an
implemenation has detected that a system has
recovered from a Bus Timeout.
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Installing the
system board). (n = microprocessor number)
816f0113-0301ffff • 816f0125-2c01ffff
816f0125-1001ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
now Present.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
816f0125-1002ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
now Present.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
816f0125-1f01ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
now Present.
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
816f0125-2c01ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
now Present.
Severity: Info
Appendix A. Integrated Management Module II (IMM2) error messages
[ManagedElementName] detected
as present. (PCI Riser 1)
[ManagedElementName] detected
as present. (PCI Riser 2)
[ManagedElementName] detected
as present. (PDB Cable)
[ManagedElementName] detected
as present. (Mezz Card)
287