[779] E1 MFC-R2 Disappearance Timer

Description
Sets the length of waiting time of the stop signal on the E1 line assigned to MFC-R2.
This programme is available for the KX-TD1232 only.
Selection
Time (seconds): 01 through 30
Default
24 s
Programming
1.
Enter 779.
Display: 779 DISAPPEAR
2.
Press NEXT.
Display example: Disappear:24
3.
Enter the time.
To change the current entry, press CLEAR and enter the new time.
4.
Press STORE.
5.
Press END.
Conditions
Adjust to a setting of the connected telephone company.