Orban OPTIMOD-FM 8500S Operating Manual page 81

Digital audio processor
Table of Contents

Advertisement

OPTIMOD-FM DIGITAL
4. Program Tally Outputs.
[Skip this step if you do not wish to use the tally outputs.]
See step 6 on page 2-4 for wiring instructions.
You can program the two tally outputs to indicate a number of different opera-
tional and fault conditions.
A) Navigate to Setup > N
B) Program tally output #1.
To program a given tally output, press and hold the soft button associ-
ated with the output you are programming. As you turn the control
knob, the functions listed below will appear in the highlighted field.
• Input: Analog: Indicates that the 8500S is processing audio from its analog
input.
• Input: Digital: Indicates that the 8500S is processing audio from its AES3
digital input.
• Analog Input Silent: Indicates that the level at either or both analog in-
put channels is below the threshold set in step 3 on page 2-24.
• AES Input Silent: Indicates that the level at either or both digital input
channels is below the threshold set in step 3 on page 2-24.
• AES Input Error: Indicates that the 8500S's AES input receiver chip has de-
tected a problem with the data being received such that the data is unus-
able. When the chip detects such an error, it automatically switches the in-
put to A
NALOG
• Sync Reference Input Error: Indicates that the 8500S has detected a
problem with the signal being received at the sync reference input such
that the signal is unusable.
When pilot sync is specified (S
such an error is detected, the 8500S automatically switches the sync source to
the digital input.
If there is no valid digital input signal at the digital input, the sync source de-
faults to the 8500S's internal clock.
• No Function: Tally output is disabled.
C) Program tally output #2 if you wish, following the procedure in step (B) above
with the T
ALLY
The following material provides detailed instructions on how to set up the 8500S. If
QUICK SETUP does not fully address your setup needs or if you wish to customize
R
ETWORK
EMOTE
.
> I/O C
ETUP
O
2 button.
UT
> R
I
> T
EMOTE
NTERFACE
> D
O
C
> DO S
ALIB
IG
UT
ALIB
INSTALLATION
1.
ALLY
) and
YNC
2-25