2-94
INSTALLATION

SNMP Support

SNMP Network Setup

SNMP Mib file

SNMP Default Settings

The SNMP (Simple Network Management Protocol) features allow you to monitor
your Optimod's status and to send Alarm notifications via your Optimod's Ethernet
connection to your network. It is beyond the scope of this manual to provide a gen-
eral explanation of how SNMP works. The text below provides sufficient information
to use your Optimod in your specific SNMP setup if you are already familiar with the
general principles of setting up SNMP.
These controls are only available from Optimod PC Remote.
In the I/O menu, select the N
SNMP (Enable/Disable): enables or disables the SNMP feature. Select "enable"
and disconnect from the PC remote to update the unit and allow SNMP access.
If you wish to disable SNMP access after it has been enabled, select "dis-
able" and then reboot your Optimod.
Primary Manager Address: (255.255.255.255) sets the address of the Primary
SNMP Manager.
Primary Manager Port: (162) sets the port of the Primary SNMP Manager.
Secondary Manger Address: (255.255.255.255) sets the address of a Secondary
SNMP Manager.
Secondary Manger Port: (162) sets the address of a Secondary SNMP Port.
The 8500S.mib file is in the location where you installed your PC Remote application.
The default 8500S install location is:
Program Files\Orban\Optimod 8500S PC Remote
or
Program Files(x86)\Orban\Optimod 8500S PC Remote
SNMP Agent: Disabled
Primary Manager(Alarm) Address: 255.255.255.255
Primary Manager (Alarm) Port: 162
Secondary Manger (Alarm) Address: 255.255.255.255
tab to access the SNMP configuration controls.
ETWORK