Table 4-1: Typical Power Supply Voltages And Ac Ripple - Orban OPTIMOD-FM 8500S Operating Manual

Digital audio processor
Table of Contents

Advertisement

OPTIMOD-FM DIGITAL
the more severe faults that could develop in the 8500S circuitry even in high-RF en-
vironments.
See the assembly drawings in Section 6 for component locations.
Be sure to disconnect the AC line cord before removing or installing circuit boards.
Follow these instructions in order without skipping steps.
Note: To obtain an unbalanced output, jumper pin 1 (ground) to pin 3, and measure
between pin 1 (ground) and pin 2 (hot).
Note: All analog output measurements are taken with a load resistance of 10K or
higher, corresponding to the modern practice of terminating analog lines with a
bridging load.
1. Test the power supply
The power supply is a module. In case of any power supply failure, the entire
supply must be replaced by an exact replacement (available from Orban Service).
Attempts to repair the supply on a component level and/or to replace the supply
with a non-approved supply may compromise your Optimod's compliance with
the EMI and safety regulations in your country.
The +3.3V, +1.2V, and +2.5V supplies are locally regulated on the DSP and
control boards (see Section 6).
Measure the power supply's regulated voltages at the DVM and observe the rip-
ple with an oscilloscope, AC-coupled. Convenient sources of these voltages are
the inductors adjacent to power supply connectors on the I/O+DSP board. Con-
nect your probe to the sides of the inductors away from the power supply con-
nectors. The results in Table 4-1 are typical.
Power Supply Rail
+15VDC
–15VDC
+5VDC

Table 4-1: Typical Power Supply Voltages and AC Ripple

2. Prepare the unit for audio measurements.
A) Use the front panel controls to set the 8500S's software controls to their de-
fault settings as follows:
a) Navigate to Setup > I/O C
settings (so you can restore them later) or saving them via PC Remote, set
controls as follows:
INPUT ............................................................................................ analog
AI Ref VU ..................................................................................... 0.0 dBu
R CH BAL.........................................................................................0.0 dB
DC Voltage (volts)
+15 ± 0.5
–15 ± 0.5
+5 ± 0.25
. After writing down the old
> A
I
C
ALIB
NLG
N
ALIB
MAINTENANCE
AC Ripple (mV p-p)
<20
<20
<20
4-7