Serial Api Commands; Adr-Projector Address; Aig-Auto Image - Christie DWU1612-HS Technical Reference

Serial commands
Hide thumbs Also See for DWU1612-HS:
Table of Contents

Advertisement

Serial API commands

The DWU1612-HS/DWU2022-HS commands can be used to modify product settings.
ADR–Projector Address
Sets or queries the device address.
This command also helps to identify where a response or asynchronous message originates from.
Generally, this command is used for projectors that are daisy-chained together using the RS232 style
communication.
The projector responds to IR remotes set to the same address as the projector or to IR remotes set to
address 0.
Commands
Command
ADR?
Checks the current projector address. (Read-only)
ADR <value>
Sets the projector address to <value>.
Examples
Set the projector address 0:
(ADR 0)
AIG–Auto Image
Sets the timing detection mode to support additional PC timings.
When the projected picture is not completed, use to adjust the picture.
Commands
Command
Description
AIG?
Returns the timing detection mode. (Read-only)
AIG <0 | 1>
Sets the timing detection mode.
Some 4:3 input sources are not recognized in Wide mode, for
example, 1400 x 1050. Use Normal mode for these sources.
DWU1612-HS/DWU2022-HS Technical Reference–Serial Commands
020-103352-01 Rev. 1 (03-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Values
0 to 9
0 (Default)
Values
0 = Normal
1 = Wide (Default)