Parameter
Keypad and
Parameter
structure
display
x.00
Gives the type/mode of the data block selected with Pr 11.37 as shown below.
Pr 11.38 String
Type/mode
0
FrEE
Value when Pr 11.37 = 0
1
3C.SE
Commander SE mode parameter file (not used)
2
3OPEn.LP
Open-loop mode parameter file
3
3CL.VECt
Closed-loop vector mode parameter file
4
3SErVO
Servo mode parameter file
5
3REGEn
Regen mode parameter file
6-8
3Un
Unused
9
4C.SE
Commander SE mode difference from default file (not used)
10
4OPEn.LP
Open-loop mode difference from default file
11
4CL.VECt
Closed-loop vector mode difference from default file
12
4SErVO
Servo mode difference from default file
13
4REGEn
Regen mode difference from default file
14-16
4Un
Unused
17
LAddEr
Onboard Application Lite user program file
A file containing user defined data (normally created by an SM-
18
Option
Applications Solutions Module)
11.39

SMARTCARD data version

Drive modes
Open-loop, Closed-loop, Servo, Regen
Bit
SP
Coding
Range
Open-loop, Closed-loop, Servo, Regen
Default
Open-loop, Closed-loop, Servo, Regen
Update rate
Background read/write
Gives the version number of the data block. This is intended to be used when data blocks are used as drive macros. If a version number is to be
stored with a data block this parameter should be set to the required version number before the data is transferred. Each time Pr 11.37 is changed by
the user the drive puts the version number of the currently viewed data block in this parameter.
11.40

SMARTCARD data checksum

Drive modes
Open-loop, Closed-loop, Servo, Regen
Bit
SP
Coding
Range
Open-loop, Closed-loop, Servo, Regen
Update rate
Background write
Gives the checksum of the data block, space left on the card, the total space on the card for the card flags see Pr 11.37 for details.
11.41

Status mode time-out

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
Sets the timeout for the drive display to revert to status mode from edit mode following no key presses. Although this parameter can be set to less
than 2s, the minimum timeout is 2s.
Unidrive SP Advanced User Guide
Issue Number: 10
Parameter
Advanced parameter
description format
descriptions
FI
DE
Txt VM DP
ND
0 to 9,999
0
FI
DE
Txt VM DP
ND
1
0 to 65,335
FI
DE
Txt VM DP
ND
0 to 250 s
240
www.controltechniques.com
Serial comms
Macros
protocol
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
Electronic
Performance RFC mode
nameplate
PS
1
PS
1
PS
1