Logic Function 2 Destination; Motorized Pot Mode; Motorized Pot Bipolar Select; Motorized Pot Rate - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Parameter
Keypad and
Menu 9
structure
display
9.10
Logic function 1 destination
9.20

Logic function 2 destination

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Read on reset
9.21

Motorized pot mode

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
The motorized pot modes are given in the following table.
Pr 9.21
Mode
0
Zero at power-up
1
Last value at power-up
Zero at power-up and only change
2
when drive running
Last value at power-up and only
3
change when drive running
9.22

Motorized pot bipolar select

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
1
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
4ms x number of menu 9 or 12 functions active read
When this bit is set to 0 the motorized pot output is limited to positive values only (i.e. 0 to 100.0%). Setting it to 1 allows negative outputs (i.e. ±100.0
%).
9.23

Motorized pot rate

Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Bit
SP
Coding
Open-loop, Closed-loop vector, Servo,
Range
Regen
Open-loop, Closed-loop vector, Servo,
Default
Regen
Update rate
Background read
This parameter defines the time taken for the motorized pot function to ramp from 0 to 100.0%. Twice this time will be taken to adjust the output from
-100.0 % to +100.0 %.
174
Parameter
Parameter
x.00
description format
FI
DE
Txt VM DP
ND
1
2
Pr 0.00 to Pr 21.51
Pr 0.00
FI
DE
Txt VM DP
ND
0 to 3
2
Reset to zero at each power-up.
Up, down and reset are active at all times.
Set to value at power-down when drive powered-up.
Up, down and reset are active at all times.
Reset to zero at each power-up.
Up and down are only active when the drive is running (i.e. inverter active).
Reset is active at all times.
Set to value at power-down when drive powered-up.
Up and down are only active when the drive is running (i.e. inverter active).
Reset is active at all times.
FI
DE
Txt VM DP
ND
0
FI
DE
Txt VM DP
ND
0 to 250 s
20
www.controltechniques.com
Advanced parameter
Macros
descriptions
RA NC NV
PT
US RW BU
1
1
1
RA NC NV
PT
US RW BU
1
1
Comments
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
Serial comms
Electronic
Performance RFC mode
protocol
nameplate
PS
1
PS
1
PS
PS
1
Unidrive SP Advanced User Guide