Terminal T7 Digital Input 3 Invert; Relay Invert; Real Time Clock Daylight Saving Mode - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Menus 15 to 17
Parameter
Keypad and
SM-I/O Lt Tmr
structure
x.14
Terminal T5 digital input 1 invert
x.15
Terminal T6 digital input 2 invert
x.16

Terminal T7 digital input 3 invert

RW
Bit
OFF(0) or On(1)
Update rate: Background read
Setting these parameters to a On causes the input sense to the destination parameter to be inverted.
x.17

Relay invert

RW
Bit
OFF(0) or On(1)
Update rate: Background read
Setting this parameter to a 1 causes the relay sense to be inverted.
x.19

Real time clock daylight saving mode

RW
Bit
OFF(0) or On(1)
Update rate: Background read
0: OFF Real time clock normal operation
1: On Real time clock + 1 hour
NOTE
This parameter is not available on the SM-I/O Lite.
x.20
Digital I/O read word
RW
Uni
0 to 120
Update rate: Background write
This word is used to determine the status of the digital I/O by reading one parameter.
Pr x.20 contains a binary value 'xx'. This binary value is determined by the state of Pr x.04 to Pr x.07. So for example, if all terminals were active the
value displayed in Pr x.20 would be the sum of the binary values shown in the table, i.e. 120.
Binary value for xx
Digital I/O
1
2
4
8
Terminal T5
16
Terminal T6
32
Terminal T7
64
Terminals T21 & T23
128
x.24
Terminal T5 digital input destination
x.25
Terminal T6 digital input destination
x.26
Terminal T7 digital input destination
RW
Uni
DE
Pr 0.00 to Pr 21.51
Update rate: Read on drive reset
Destination parameters define the parameter each of the programmable inputs is to control. Only parameters that are not protected can be controlled
by the programmable digital inputs. If a non-valid parameter is programmed, the digital input is not routed anywhere.
300
Parameter
Parameter
display
x.00
description format
US
OFF(0)
US
OFF(0)
US
OFF(0)
NC
PT
0
PT
US
Pr 0.00
www.controltechniques.com
Advanced parameter
Macros
descriptions
Serial comms
Electronic
Performance RFC mode
protocol
nameplate
Unidrive SP Advanced User Guide
Issue Number: 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents