I/O Module Slot Definitions - HPE ProLiant XL250a Gen9 Maintenance And Service Manual

Table of Contents

Advertisement

IMPORTANT: When installing a HPE ProLiant XL250a Gen9 Server, be sure that only I/O
module blanks are installed in the even-numbered I/O module bays. Failure to do so may
cause the I/O modules in the even-numbered bays to disengage or to be damaged.
I/O modules are specific to each server and are installed in the rear of the chassis.
The chassis has ten I/O module bays located in the rear of the chassis. I/O module blanks are supported
in all even-numbered bays and I/O modules are supported in all odd-numbered bays.
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).

I/O module slot definitions

Item
Dual FlexibleLOM I/O module
slot description
FlexibleLOM 1 — PCIe3 x16 (16,
1
8, 4, 2, 1)
FlexibleLOM 2 — PCIe3 x8 (8, 4,
2
2, 1)
PCIe/FlexibleLOM I/O
module slot description
FlexibleLOM — PCIe3 x8 (8, 4,
2, 1)
PCIe LP — PCIe3 x16 (16, 8, 4,
2, 1)