Processor - HPE ProLiant XL250a Gen9 Maintenance And Service Manual

Table of Contents

Advertisement

Install all drives
16.
Install the server into the chassis
17.
Connect all peripheral cables to the server.
18.
Press the Power On/Standby button.
19.
The server exits standby mode and applies full power to the system. The system power LED
changes from amber to green.

Processor

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent possible server overheating, always populate each processor socket
with a processor socket cover and a heatsink blank or a processor and a heatsink.
IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty,
the server does not power up.
To remove the component:
Update the system ROM.
1.
Locate and download the latest ROM version from the Hewlett Packard Enterprise website
(http://www.hpe.com/support). Follow the instructions on the website to update the system ROM.
Power down the server (on page 28).
2.
Disconnect all peripheral cables from the server.
3.
Remove the server (on page 28).
4.
Place the server on a flat, level work surface.
5.
Disconnect the intra-tray signal cable from the power expander board.
6.
Remove all drives from drive cage assembly 2
7.
Remove drive cage assembly 2
8.
Disconnect and remove the drive cables connected to drive cage assembly 2
9.
page 91).
("Removing and replacing a
("Install the
("Drive cage assembly
drive" on page 35).
server" on page 33).
("Removing and replacing a
2" on page 58).
Removal and replacement procedures 65
drive" on page 35).
("Drive
cabling" on

Advertisement

Table of Contents
loading

Table of Contents