Follow steps 1 through 6 of Exposure Lamp Replacement.
1 .
2 .
Remove the accuride rail (3 screws).
Remove the pulse generator bracket (1screw).
3 .
4 .
Take off the slider clutch bracket (3 screws) and unhook the slider stopper spring from the
bracket. (Do not break the slider stopper pin.
5 .
Remove slider drive gear.
Take off the rear exposure lamp terminal (1 small screw).
6 .
7 .
Disconnect the 2P connector on the ac drive board.
8 .
Remove exposure lamp heater.
NOTE: 1. When installing the new exposure lamp heater, use the old spring.
2. After reassembling, make sure the slider stopper spring and pin are securely
mounted.
(See page 3-22.)