– Fusing Thermoswitch –
Follow steps 1 through 4 of Fusing Lamp Replacement. (See page 3-70.)
Open the exit cover and remove the fusing unit cover (2screws).
Take off the top frame (2screws).
Remove the thermoswitch (2screws).
careful not to damage the pressure and hot rollers.
NOTE: Be
3 - 7 4
25, 1985