3.

Replacement of Parts

Charge Corona Wire –
1 .
Open the upper clamshell and
(Do not place the master unit where it will be exposed to strong light.)
2 .
Unplug the high voltage cable from the power pack.
3 .
Remove the charge corona unit (1 stud screw).
4 .
Remove the front cover gently using a small screwdriver as shown in the above figure.
5 .
Remove the rear cover gently, then remove the corona wire.
6.
Replace the charge corona wire as shown in the above figure.
Hook the large eyelet of the wire to the stud screw.
Hook the small eyelet
stretch the spring or break the wire.)
Check that the wire is in the "V" slot of both endblocks.
- Install the front cover.
NOTE: Confirm that the cable is behind the quenching lamp.
.-. .
Front Cover
remove the master
of the wire to the front cover spring; install the rear cover.
unit.
3 - 6
May, 25, 1985
Rear Endblock
(Do not