– Charge Corona Power Pack –
Ground Wire
1. Remove the front cover.
(See page 3-79.)
2. Disconnect the 3P connector from the power pack.
3. Remove the ground wire from the frame (1 screw).
4. Remove the charge power pack (1 screw).
5. Unplug the high voltage cable from the power pack.
NOTE: The ground wire must securely contact the frame.