3-1-2.
JP3E8600 keyboard specification and function description (Optional)
Forward Indication Light
* ON : forward indication
* OFF : not forward indication
* FLASH : forward accelerating
Monitor Select 1 Numerical Display
* display the corresponding values of the
function under query status
* display fault code under fault condition
* display the object set byA00 monitor
select while running
Positive And Negative Sign Indication Light
* just for monitor select
Parameter Setting/Shift Key
* start to change parameter
* Functions value adjustments
Modification bit
Multi-function Key MF1/MF2
* MF1 define functions through parameter
A43
* MF2 define functions through parameter
A44
* A43/A44=0 MF defined as plus function
* A43/A44=1 MF defined as minus function
* A43/A44=2 MF defined as free stop
function
* A43/A44=3 MF defined as forward
function
* A43/A44=4 MF defined as reverse
function
* A43/A44=5 MF defined as Punctuality
dynamic function
* A43/A44=6 MF defined as Anti-Jog
function
* A43/A44=7 MF defined as Jog function
* A43/A44=8 MF defined as Up function
* A43/A44=9 MF defined as Down function
Reverse Lndication Light
* ON : reverse indication
* OFF : not reverse indication
* FLASH : reverse accelerating
FWD
REV
%
+
Hz
PRG
SET
MF1
ESC
MF2
Acceleration Select/Parameter
Quit Key
Setting Key
* exit the revisement of
* press SET key and rotate JOG key
parameter
while selecting parameter, the
* reture to displaying menu
parameter location changes to 10
from submenu or functional
* finish and save the value changes
menu
* change the object under monitor
* exit default state
9
Section III Operation Keyboard
Alarm Indication
Light
* ON : faulty
* OFF : good
* FLASH : previous
fault was not
confirmed
ALARM
° C
S
A
v
ENTER
* have the same function with PRG/
, refer to explaination of key PRG/
* Invalid in the monitoring state
Potentiometer Key
* under checking state, the
FWD
* under revising state, the edit bit
STOP
RESET
* under monitoring, setting
Data Unit Prompt Light
*composed of three indication
lights , located on the right side of
the LED digital tube , Display
status corresponding to the six
units , indicate the unit of the
parameters displayed by LED 。
*the correspondence is as
following :
UNIT
UNIT
UNIT
UNIT
Hz
Hz
Hz
Hz
%
%
%
%
A
A
A
A
° C
° C
° C
° C
S
S
S
S
V
V
V
V
NO UNITS
Hz
A
V
UNIT
UNIT
UNIT
Hz
Hz
Hz
%
%
%
ON
A
A
A
° C
° C
° C
S
S
S
OFF
V
V
V
S
° C
%
function items value has been in
increment or decrement
of function items value has been
in increment or decrement
frequency to increase or decrease
Forward running key
* drive forward running
Reset /Stop Key
* drive stop running
* Exception Reset
* fault confirmation