Powtran PI8600 F Series User Manual page 80

Frequency inverters
Table of Contents

Advertisement

Section V Parameter Function Table
1 bit: UP acceleration mode
0: Fix speed acceleration, according to A41 fix speed: To increase frequency every 200ms.
1: Fix times acceleration, according to fix times: To increase frequency every triggering.
10 bit: DN deceleration mode
0: Fix speed deceleration, according to A42 fix speed: To reduce frequency every 200ms.
1: Fix times deceleration, according to A42 fix times: To reduce frequency every triggering.
100 bit: UP adjustment mode of adjusting speed ratio
0
UP N adjustment of speed ratio
AI1 adjustment of the external
1
8000
analog giving
AI2 adjustment of the external
2
analog giving
AI3 adjustment of the external
3
8000
analog giving
Adjustment of potentiometer
4
giving
Adjustment of multi-steps digital
5
voltage
1000 bit: DN adjustment mode of adjusting speed ratio
0
N adjustment of acceleration time
AI1 adjustment of the external
1
8000
analog giving
AI2 adjustment of the external
2
analog giving
AI3 adjustment of the external
3
8000
analog giving
Adjustment of potentiometer
4
giving
Adjustment of multi-steps digital
5
voltage
A40
UP/DN adjustment value
Frequency after adjustment=set frequency + UP/DN adjustment value.
A41
UP adjustment ratio
Fix speed: To increase frequency every 200ms.
Fix times: To increase frequency every triggering.
A42
DN adjustment ratio
Fix speed: To reduce frequency every 200ms.
Fix times: To reduce frequency every triggering.
The definition of
A43
multifunction keys MF1
A44
and MF2
No adjustment
-
Actual UP adjustment ratio= percentage given by
A41*AI2
Actual UP adjustment ratio= percentage given by
A41*AI3
Actual UP adjustment ratio= percentage given by
A41* potentiomet
Actual UP adjustment ratio=percentage given by
A41* multi-steps digital voltage
No adjustment
-
Actual DN adjustment ratio =percentage given by
A42*AI2
Actual DN adjustment ratio=percentage given by
A42*AI3
Actual DN adjustment ratio=percentage given by
A42*AI3.
Actual DN adjustment ratio=percentage given by
A42*multi-steps digital voltage.
-300.00~300.00
0.01~20.00
0.01~20.00
MF is defined as adding
function key
MF is defined as reducing
function key
MF is defined as free
78
-
0.00
Hz
0.01
Hz
0.01
0
-
0
1
-
1
2
N
Y
Y
Y
Y

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pi8600 g series