Powtran PI8600 F Series User Manual page 129

Frequency inverters
Table of Contents

Advertisement

Keyboard figures area show "CAL1", inverter without output.
Keyboard figures area show "CAL2", inverter with output, static state.
Keyboard figures area show "-END": measuring ends.
Keyboard figures area show "E. CAL": the measurement process errors.
Process can be measured through the STOP key to stop.
3 : Inverter rotation measurement
Motor can be measured without load, can choose the rotation measurement. Measurements
started, make sure the motor is static.Static measurement converter, the output DC voltage,
pay attention to safety.
The b11 is set to 3, the inverter automatically start parameter determination.
Keyboard figures show that the regional show "-RUN": waiting to run the command, start
the measurement.
Keyboard figures area show "CAL1", "CAL3": N output inverter.
Keyboard figures area show "CAL2", inverter with output, under static state.
Keyboard figures area show "CAL4", inverter with output, the motor forward in high-speed.
Keyboard figures area show "-END": measuring the end.
Keyboard figures area show "E. CAL": the measurement process errors.
Process can be measured through the STOP key to stop.
Set this parameter,the motor parameters will be determined dynamically.Be sure the motor
is without load (N-load operation). Before setting,be sure to run well prepared,the motor will
run in high speed during the measurement
Measurement is completed, b11 return to 0. The measured parameters will select parameters
on the base of b10 motor parameters which is automatically saved to the b05 ~ b09 or b18 ~
b22.
Note: Before auto-measure the motor parameter, must input motor rated parameter b00~b04
or b13~17 correctly
Please regulate accelerating and deceleration time or torque increasing parameter, if there is
over -current or over voltage faults while auto- measurement.
When automatic regulation, motor should be in stop status
Vector control initial
b12
inspection R1
b13
Motor 2 rated frequency
b14
Motor 2 rated current
b15
Motor 2 rated voltage
b16
Motor 2 pole pairs
b17
Motor 2 rated speed
b18
Motor 2 N load current
b19
Motor 2 stator resistance
b20
Motor 2 rotator
b21
Motor 2 stator inductance
b22
Motor 2 mutual inductance
The 2nd group motor parameters can be set by system. The definition is same with group 1.
Section V Parameter Function Table
Not inspection R1
Inspection R1
0.00~Max frequency
y09*(50%~100%)
100~1140
1~8
500~5000
0.0~b14
0.000~30.000
0.000~30.000
0.0~3200.0
0.0~3200.0
127
0
-
0
1
Hz
50.00
A
V
-
2
rpm
1480
A
ohm
ohm
mH
mH
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pi8600 g series

Table of Contents