After multi-digital voltage terminal effective switch, change F01keyboard setting.
1 : AI1 the external analog setting
Given the external analog0~10V,-10V~+10V,0~20mA.For detail please read the o group
parameter.
2 : AI2 the external analog setting
Given the external analog 0~10V, 0~20mA.For detail please read the o group parameter.
3 : AI3 the external analog setting
Given the external analog 0~10V, 0~20mA.For detail please read the o group parameter.
4 : Keyboard potentiometer setting
Keyboard potentiometer setting, keyboard potentiometer for a given start and end values of
the corresponding values can be positive role and negative effects. For detail please read the
A group parameter.
5 : Multi-segment digital voltage setting
o36~o46 IO input terminal function set to 11, 12, 13, switch H47~H54 Multi-digital
voltage setting, 100% Corresponding to the maximum frequency .
6 : Digital pulse set
Digital pulse input frequency corresponding to set the frequency, For detail please read o52
parameter.
Pulse input terminal and DI8 terminal reseting, After use digital pulse input, o43set to 0,
Otherwise, the function settings will take effect, can check the pulse input status o58, be
limited to low-speed pulse.
7 : PID regulation mode
The completion of the main to the frequency of common analog feedback loop control.
Speed control accuracy requirements applicable to the general occasions.
The given value can be given through the keyboard can also be given through the analog.
Analog feedback can represent the pressure, flow, temperature.
Details see the P group of parameters.
The completion of the main to the frequency of common analog feedback loop control.
Speed control accuracy requirements applicable to the general occasions.
For a given value can be given through the keyboard can also be given through the analog.
Analog feedback can represent the pressure, flow, temperature.
Details see the P group of parameters.
Through o36~o46 IO input terminal, set to 17, 18, 19 be configured to switch the source for
a given ratio.
The relationship between
F04
main and auxiliary setting
frequency
Section V Parameter Function Table
The main setting individual
control
The auxiliary setting
individual control
Main + auxiliary
Main -auxiliary
(main*auxiliary)/maximum
frequency
Maximum{main,auxiliary} 5
55
0
1
2
-
0
3
4
Y