3. PERIODIC CHECK
3.4.2
Replacing the filter cover assy and the suction filter /A assy
A. Periodically replaced parts/cycle
•
Filter cover assy
•
Suction filter /A assy
*1
501/421
*2
361
B. Procedure
22
: Every 250,000 prints *1
: Every 225,000 prints *2
: Every 250,000 prints *1
: Every 225,000 prints *2
[1]
[2]
50gaf2c015nb
[1]
50gaf2c016na
Field Service Ver.2.0 Mar. 2009
1.
Remove the screw [1] and then remove the filter
cover assy [2].
2.
Remove the suction filter /A assy [1].